SONOELASTOGRAPHIC DIFFERENCES IN BREAST TISSUE ELASTICITY BETWEEN WOMEN USING AND NOT USING HORMONAL CONTRACEPTIVES

Authors

Keywords:

breast sonoelastography; hormonal contraception; breast elasticity; menstrual cycle; shear-wave elastography; strain elastography.

Abstract

Breast tissue elasticity is a physiological property that may vary with age, hormonal status and the menstrual cycle. Sonoelastography offers a non-invasive way to assess tissue mechanical properties, but interpretation requires attention to acquisition technique and biological variation.

 

Objective: To critically review evidence on sonoelastographic breast tissue elasticity in women using and not using hormonal contraceptives and to identify methodological priorities for future comparative research.

 

Methods: A focused, non-systematic narrative review was prepared using targeted searches of biomedical literature and professional guidance available by 19 October 2026. Sources were selected for direct relevance to breast sonoelastography, menstrual-cycle variation and elastography methods. No meta-analysis or formal risk-of-bias assessment was performed.

Synthesis: A small longitudinal study of 22 healthy women reported cycle-related changes in breast parenchymal elasticity among women not using hormonal medication, whereas statistically significant cycle-dependent changes were not observed in the oral-contraceptive group. The study also reported differences between groups. These findings are relevant but cannot be generalized without caution because of the small sample and specific study conditions. International guidance emphasizes standardized acquisition and cautious interpretation.

Conclusion: Existing evidence suggests that hormonal status and menstrual-cycle timing may influence breast sonoelastographic measurements. Larger, well-designed studies using standardized protocols, clearly defined contraceptive exposures and appropriate control of physiological factors are needed before clinical thresholds or causal conclusions can be proposed.

 

References

1.Wojcinski S, Cassel M, Farrokh A, Soliman AA, Hille U, Schmidt W, Degenhardt F, Hillemanns P. Variations in the Elasticity of Breast Tissue During the Menstrual Cycle Determined by Real-time Sonoelastography. J Ultrasound Med. 2012;31(1):63–72. https://doi.org/10.7863/jum.2012.31.1.63

2.Bamber J, Cosgrove D, Dietrich CF, et al. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology. Ultraschall Med. 2013;34(2):169–184. https://doi.org/10.1055/s-0033-1335205

3.Cosgrove D, Piscaglia F, Bamber J, et al. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications. Ultraschall Med. 2013;34(3):238–253. https://doi.org/10.1055/s-0033-1335375

4.Lee SH, Chang JM, Cho N, et al. Practice guideline for the performance of breast ultrasound elastography. Ultrasonography. 2014;33(1):3–10. https://doi.org/10.14366/usg.13012

5.Barr RG, Nakashima K, Amy D, et al. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: Breast. Ultrasound Med Biol. 2015;41(5):1148–1160. https://doi.org/10.1016/j.ultrasmedbio.2015.03.008

6.Shiina T, Nightingale KR, Palmeri ML, et al. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 1: Basic principles and terminology. Ultrasound Med Biol. 2015;41(5):1126–1147. https://doi.org/10.1016/j.ultrasmedbio.2015.03.009

7.Cosgrove DO, Berg WA, Doré CJ, et al. Shear wave elastography for breast masses is highly reproducible. Eur Radiol. 2012;22(5):1023–1032. https://doi.org/10.1007/s00330-011-2340-y

8.Goddi A, Bonardi M, Alessi S. Breast elastography: A literature review. J Ultrasound. 2012;15(3):192–198. https://doi.org/10.1016/j.jus.2012.06.009

9.Barr RG. Sonographic breast elastography: A primer. J Ultrasound Med. 2012;31(5):773–783. https://doi.org/10.7863/jum.2012.31.5.773

10.Ricci P, Maggini E, Mancuso E, Lodise P, Cantisani V, Catalano C. Clinical application of breast elastography: State of the art. Eur J Radiol. 2014;83(3):429–437. https://doi.org/10.1016/j.ejrad.2013.05.007

11.Sigrist RMS, Liau J, El Kaffas A, Chammas MC, Willmann JK. Ultrasound elastography: Review of techniques and clinical applications. Theranostics. 2017;7(5):1303–1329. https://doi.org/10.7150/thno.18650

12.Youk JH, Gweon HM, Son EJ. Shear-wave elastography in breast ultrasonography: The state of the art. Ultrasonography. 2017;36(4):300–309. https://doi.org/10.14366/usg.17024

13.Hong MJ, Kim HH. Intra- and interobserver reproducibility of shear wave elastography for evaluation of the breast lesions. J Korean Soc Radiol. 2017;76(3):198–205. https://doi.org/10.3348/jksr.2017.76.3.198

14.Evans A, Whelehan P, Thomson K, et al. Differentiating benign from malignant solid breast masses: Value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification. Br J Cancer. 2012;107(2):224–229. https://doi.org/10.1038/bjc.2012.253

Published

2026-10-20